Low Energy Electromagnetic models data files
============================================

    *********************************************************************
    * DATA ARE *NOT* FOR COMMERCIAL USE AND MUST BE USED WITHIN GEANT4  *
    *********************************************************************

========================================================================= 

Directory Description
=====================

Photon data that are based on EPICS2017

=========================================================================
Gamma conversion (pair): pair + triplet production

G4LivermoreGammaConversionModel, G4LivermoreGammaConversion5DModel

description   directory             file name      file type                                 database     interpolation
              epics2017/pair        pp-cs-NN.dat   gamma conversion cross sections(sum)      EPICS2017    linear

Each pp-cs-NN.dat is composed of two header lines and a data table 

               column 1                 column 2         column  3
  line 1:      minimal energy           maximal energy   number of data lines
  line 2:      number of data lines  
  data line:   energy (MeV)             CS (mm2)
  data line:
  data line:
  ...
  
NB:interpolation is the interpolation method when calculating the cross section according to the tabulated data
  
The following data files in livermore directory are not read by model classes:	
	  
description   directory             file name           file type                            database     
              livermore/pairdata    pp-pair-cs-NN.dat   pair production cross sections       EPDL97       
              livermore/tripdata    pp-trip-cs-NN.dat   triplet production cross sections    EPDL97       

========================== 

Compton effect (comp):

G4LivermoreComptonModel

description   directory             file name      file type           database     interpolation
              epics2017/comp        ce-cs-NN.dat   cross sections      EPICS2017    linear

Each ce-cs-NN.dat is composed of two header lines and a data table 

               column 1               column 2          column  3
  line 1:      minimal energy         maximal energy    number of data lines
  line 2:      number of data lines
  data line:   energy (MeV)           energy*CS(MeV*barn)
  data line:
  data line:
  ...
  
NB:
(1) interpolation is the interpolation method when calculating the cross section according to the tabulated data
In consistency with Geant4 10.6, linear is adopted when using EPDL97 
(2) the 2rd column of data lines is the production of energy and cross section, instead of pure cross section
  
========================== 

Photoelectric effect (phot): 
 
G4LivermorePhotoElectricModel

description   directory                   file name         file type                                            database     interpolation
              epics2017/phot              pe-cs-NN.dat      total cross sections above K shell binding energy    EPICS2017    linear
              epics2017/phot              pe-le-cs-NN.dat   total cross sections below K shell binding energy    EPICS2017    linear
              epics2017/phot              pe-high-NN.dat    high fitting parameters for subshell cross sections  EPICS2017    
              epics2017/phot              pe-low-NN.dat     low fitting parameters for subshell cross sections   EPICS2017    
              epics2017/phot              pe-ss-cs-NN.dat   subshell cross sections                              EPICS2017    
			
 pe-cs-NN.dat and pe-le-cs-NN.dat have save structure, each file is composed of two header lines and a data table 

               column 1               column 2                                      column 3
  line 1:      minimal energy         maximal energy                                number of data lines
  line 2:      number of data lines
  data line:   energy (MeV)           energy*energy*energy*CS (MeV*MeV*MeV*barn)
  data line:
  data line:
  ...
  
NB:
(1) interpolation is the interpolation method when calculating the cross section according to the tabulated data
In consistency with Geant4 10.6, linear is adopted when using EPICS2014
(2) the 2rd column of data lines is the production of cube of energy and cross section, instead of pure cross section
   
   
pe-high-NN.dat and pe-low-NN.dat have same structure

                 column 1              column 2                          column 3
   line 1:       number of subshell    number of subshell                low or high energy limit
   
                 column 1              column 2-7
   line 2:       1st binding energy    low or high fitting parameters
   line 3:       2nd binding energy    low or high fitting parameters
   line 4:       
   ...


Each pe-ss-cs-NN.dat file is composed of several data tables, the number of data tables corresponds to the number of subshells
Each data table has same structure

                 column 1            column 2                                      column 3                column 4 
   line 1:       minimal energy      maximal energy                                number of data lines    subshell index
   data line:	 energy (MeV)        energy*energy*energy*CS (MeV*MeV*MeV*barn)	
   data line:
   data line:
   ...
 
NB: 
(1) subshell index starts from 0 to S-1, S is the number of subshells
(2) the 2rd column of data lines is the production of cube of energy and cross section, instead of pure cross section

========-================== 

Rayleigh scattering (rayl):

G4LivermoreRayleighModel

description   directory         file name      file type         database     interpolation
              epics2017/rayl    re-cs-NN.dat   cross sections    EPICS2017    linear

Each re-cs-NN.dat is composed of two header lines and a data table 

               column 1            column 2                        column  3
  line 1:      minimal energy      maximal energy                  number of points
  line 2:      number of points
  data line:   energy (MeV)        energy*energy*CS (MeV*MeV*mm2)
  data line:
  data line:
  ...
  
NB:
(1) interpolation is the interpolation method when calculating the cross section according to the tabulated data
In consistency with Geant4 10.6, linear is adopted when using EPDL97
(2) the 2rd column of data lines is the production of square of energy and cross section, instead of pure cross section